Stationary Analog X Ray

$7,400.00

This stationary analog x ray machine of 300ma can meet the requirement of 220V power supply and make x ray photography.

SKU: NKX-300A Category: Tag:

Stationary Analog X Ray

This stationary analog x ray adopts analog work frequency generator or high frequency generator. The table surface is floating in 4-ways.

Model: NKX-300A
stationary analog x ray
stationary 300ma x ray

Characters

1. The supply voltage V and photography kV of this stationary analog x ray machine are generated by motors, which are all of infinitely variable control.

2. The machine is equipped with an interlocking protecting circuit device and takes the interlocking protection with grading to the three photographic parameters (kV, mA and S).which can start immediately to stop photographing, once the selected photographic condition exceed the rated value while operating. So as to ensure the safety of the machine, meanwhile the overload lamp on the control desk may light with buzzing to warn to remind operator selecting the photographic condition again.

3. The machine is equipped with a high-voltage compensating circuit to guarantee the output of exact tube voltage under the condition of rated supply voltage drop and voltage drop produced by the internal resistance of machine. Meanwhile there is a capacitor-resonance magnetic saturation manostat and a space charge compensator in the filament heating circuit of X-ray tube unit to ensure the mA value of output of X-ray being stable within the given range.

4. The timer of loading (exposure) time of the machine adopts digital circuit, which can control time exactly and grade according to R10 preferred coefficient. The each grade has a reasonable increment.
5.  Control with the hand brake button during general photography.The button has two grades. Press the first grade, the rotary anode stars.After 1.2s of starting delay, it will enter the normal operation. Then press the second grade, the exposure begins at once and till the and of exposure time. The exposure will stop at once if loosen the hand brake button midway. If 1.2s of delay hasn’t ended, press the second grade, it will begin exposure automatically after the delay ends.
6. After the machine starts, if haven’t select the mA selector or technical selector, the buzzer will ting to remind operator.
7. During photographic exposure, the buzzer can ring in the same time, and the yellow signal lamp on the panel lights to tell operator.

8. The photographic bed is equipped with a vibration ray-filter device, which operate easy and has the remarkable results in reducing the scattering ray and raising the contrast degree of picture.

9. Then main circuit adopts the zero phase trigger of silicon control.

Pictures
fixed x ray 300ma
fixed x ray 300ma
300ma x ray machine
analog generator and console
stationary x ray table
x ray floating table

Specification
  • Power supply Adjustable range: (1) with power supply 380V 340V–420V; (2)with power supply220V 195V–250V
  • Photography Adjustable range of tube voltage: 50-125kV (Can adjust continuously)
  • Adjustable range of tube current: small focus: 50,100mA; big focus: 50,100,200 and 300mA
  • Adjustable range of time: 0.04~6.3s, 23 grades together
  • High-voltage Generator unit: capacity 29 kVA at instant 0.4 kVA at running
  • Max DC output voltage: 125 kV
  • Max DC output current : 300mA at instant; 5mAat running
  • X-ray tube model: XD51-20.40/125

Online Service

Email: [email protected] 

Mob: +86 13791899922

Find More Information 

Product

Moments

Contact

 

Weight 670 kg
Dimensions 244 × 113 × 102 cm
Type

Analog

Color

White

You may also like…