75kvdc Cable with CA11 Plug
75kvdc cable with CA11 plug is compatitable to Varex or Claymount cable, customize cable length is available.
Model: NK-75KV 8M CA11
Highlight
Highly flexible, small diameter, low capacitance, 4-conductor, 75 kVDC rated rubber insulated high voltage cable.
Featrues
• Low capacitance.
• High flexibility.
• Small diameter.
• 95% shielding braid coverage.
• RoHS compliant
Applications
• Medical X-ray equipment like standard X-ray, computed tomography and angiography equipment.
• Industrial and scientific X-ray or electron beam equipment like electron microscopy and X-ray diffraction equipment.
• Low power high voltage test and measuring equipment.
Specifications
Number of conductors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Rated voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 kVDC
Routine test voltage (high voltage insulation) ……….. 120 kVDC / 10 min
Rated voltage (conductor insulation) . . . . . . . . . . . 750 VACrms / 1000 VDC
Rated voltage (yellow cond. insulation.) . . . . . . . 1500 VACrms / 2000 VDC
Maximum conductor current . . . . 1.8 mm2: 15 A; 0.5 mm2: 8 A; 0.75 mm2: 9 A
Corona level at 75kVDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤10 pC
Nominal outside diameter . . . . . . . . . . . 21.3 mm ±0.5 mm / 0.839 in ±0.020 in
Insulation resistance core to shield @20°C . . . . . . . ≥5×1012 Ω·m / ≥15×1012 Ω·ft
Conductor resistance bare conductor @20°C . . . 8.4 mΩ/m / 2.8 mΩ/ft / ±10%
Conductor resistance red/white cond. @20°C . 10.0 mΩ/m / 3.1 mΩ/ft / ±10%
Conductor resistance yellow cond. @20°C . . . . . 37.1 mΩ/m / 12.6 mΩ/ft / ±10%
Shield resistance @20°C . . . . . . . . . . . . . . . . . . . . . . . . ≤14.8 mΩ/m / ≤4.9 mΩ/ft
Capacitance between conductors and shield . . . 145 pF/m / 48 pF/ft / ±10%
Capacitance between yellow and bare cond. . . . . . . . . . . 120 pF/m / 39 pF/ft
Cap. between red/white and bare conductor . . . . . . . . 300 pF/m / 98 pF/ft
Cable min. bending radius (static installation) . . . . . . . . . . . . . . 42 mm / 1.7 in
Cable min. bending radius (dynamic installation) . . . . . . . . . . . . 84 mm / 3.3 in
Operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10/+70°C / +14/+158°F
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40/+70°C / -40+158°F
Net weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610 kg/km